Tasmota pulsetime example github If it doesn't fail it sets it to 0. No-go. I am using a basic SonOff with Tasmota 5. I have a little different setup. To associate your I'm using it to power a multi-port USB power adapter supplying power to run a Raspberry PI server farm and want to be able to bounce the farm remotely with a single toggle. 4. maybe someone know where do I need to look to try to change how it is displayed for example like this: Activate PulseTime for one or more relays 1-8 and you can see his effect on correspondent relay 9-16 when you click correspondent relay. Before finding Tasmota, I wrote some custom code to this and it took a little while to get debouncing to work well. Therefore Power1 ON command will not be Alternatively you can use Pulsetime to fix a duration and use RuleTimer to trigger the power on at a variable period. 0 Pre-compiled; Self-compiled IDE / Compiler used: That means that a channel 99% of the time is for example 3us and then PulseTime 7 // Send ON and OFF as the switch is ON or OFF switchmode1 1 switchmode2 1 Great Thanks. You don't want to block the entire Tasmota for 10 minutes. Option 3 looks better indeed. It is counting and I can see it on Grafana, so MQTT works. With PulseTime you can even define exactly the duration of the pulse. PIR motion sensors, albeit called sensors, are configured as switches in Tasmota since they basically report motion (1) or no motion (0) to the device. h because with the latest release version I can't use WiFi Smart Config (I use it without problems on versions 5. The code looks like dis at the Enable to set time limit for power on / off state. md Added link to the orphan TouchPin page * Update Device-Groups. It is used when you power on the output, Turning off RGBCWWW bulbs crashes Tasmota. 3. What I use for my Outside Lights: Then we would be back at square ONE where every feature configured would need another compilation. This is the default behavior. I m using Tasmota to count pulses from energy-meter. Navigation Menu Toggle navigation. ino and DEBUG_DRIVER_LOG example in xdrv_09_timers. A common use for a timed device is to be active between two times. Currently we solve this by this nasty piece of code: # Create self repeating rule rule1 on Rules#Timer=1 do backlog power on; ruletimer 300 endon # Auto Turn of Example: Ruletimer1=Ruletimer1+100. In this Any chance to configure this firmare to act on the relay like a push button? E. 1 You must be logged in to vote. Skip to content. Once Pulsetime is configured, you can use a rule such as on system#boot do ON - marks the beginning of a rule <trigger> - what condition needs to occur for the rule to trigger DO - statement marking end of trigger and beginning of command part <command> - command that is executed if the <trigger> condition is met ENDON - marks the end of a rule. However you can change the base timeout with MqttRetry command But nevertheless, without changing Tasmota code, on each failing retry the timeout will increase until it reaches 120 seconds. I can do that easy with Home assistant, but I have some use case where I need to do this, with a single Tasmota device, nothing else. All this is a very good example. B so(3 1 115200) delay(50) I have sourced Tasmota again from GitHub and compiled again a version that is supporting script this morning as the status has changed to "merged". in configure module / module I opened an issue and proposed a quick and dirty fix. All reactions. Example Datasheet: Switchmode 16. Servo holds the wheels in the wanted direction, The cats need feeding so tomorrow I will go to a plain c++ sketch which I know works and come back to a tasmota implementation in September. Beta Was this translation helpful? Sign up for free to join this conversation on GitHub. Navigation Menu This example will use a variable storing the temperature to be used together with humidity in one Domoticz MQTT message. I just tested the code change above and it did in fact fix my issue. Does using a delay 600 in a rule blocks in some way the operation of Tasmota (say for power up , delay and power down), or using PulseTime better ? You probably mean The number of existing pulsetimers in tasmota is untouched (MAX_PULSETIMERS = 32). but maybe PulseTime feature may be relevant. Beta Was this translation helpful? Give feedback. Pulse timer is for calculate instantaneous active power [Watts]. I bought a few Sonoffs (Basic, TH, POW, SV) already loaded w Hello Github people, Right now I'm trying to implement a Tasmota ESP8266 smart relay device. One event/rule per power channel, if you want multiple channels. All Sign up for free to join this conversation on GitHub. I'm aware of how to use PulseTime with garage door opener applications with Tasmota - but just want the inverse. If the "ideal" is not possible than I would take any reading (like time between pulses for example) but averaging is essential as I don't want to overwhelm the MQTT channel with 100s reports per second. My Rule1 does only work with SwitchMode1 13 the example on tasmota. i. Since this is unrelated to Tasmota, I am closing this issue. 0 to use as a momentary switch. When it restarts it turns the power on to the output (for 2 sec as set in PulseTime) even though the PowerOnState is set to zero. This is a common practice when a connection timeouts. Rule1 The documentation in Tasmota and Berry is very complete, except there are very few examples. i'm working on a dual relay where i set up PulseTime to 5 through the mqtt commands. I was trying to point you in the hopefully right direction. 14 (last with millis). I'd like to use it like a software-based push-button. I have tried a water flow sensor yf-s201 but I have a problem when I install it to the water system and compare the reading of the manual meter with the water flow sensor there reading has a very big variance example in the manual A Backlog command without an argument clears a possible existing Backlog queue. There are three shutter modes which are defined according to the PulseTime and Interlock settings. x) Searched the problem in issues and in the wiki Hardware used : Bare ESP1 Issue description: PulseTime provided by Tasmota is not the same when sending an 'ON' command via mqtt or via URL. Guide and example for storing and visualizing data from tasmota devices. ShutterMode 0 - Normal Operation First relay: OFF/DOWN, Second relay: OFF/UP The pulsetime will also be triggered when I manually turn power1 to on. Getting every n seconds can be PulseTime 1900 to turn power off automatically after 30 minutes; All reactions. In Tasmota, using a Button or Switch is not the best way to interface with these The basic answer is still to create rules, like using the Event command and rule triggers to match, with the time as a parameter. thanks in a for outer garage doors, I agree with you. But if the Sonoff Device has no power at the trigger time, then, when it powers up, the light will be off To control a device locally 16 Timers are available. Rule2 At 0:00 VAR1 should be zero'd. e. Is there a rule I can use so Tasmota publishes both the totalizer value (C1) and a daily value. I'd be happy to submit a few. I set up the PulseTime to 20 for 2 second. You signed in with another tab or window. 1 Documentation. @ahmaddxb you can use normal relays with a pulsetime to insure only a brief on pulse will occur. Setting PulseTime is a lil bit complicated explained in the Tasmota WIki. ) Originally the granularity was set to 0. 14. 01. If I publish "ON" to MQTT topic 'cmnd/sonoff-comando/POWER' (switch portao_garagem_predio in Home Assistant), PulseTime seems not to be fulfilled as defined (1. The rest is done by fhem. Answer selected by 13. BREAK will stop the You signed in with another tab or window. 0, an created a counter on GPIO15. 168. 3(tasmota)-2_7_4_9(2022-01-25T09:33:35) D RCL=0. If I start a Relay (in my example Relay2) To send commands and view responses you'll need an MQTT client. None - stop pulsetimer, 0-5 re-start pulse timer to pulsetime. arendst / Tasmota Public. Everything works fine till the Sonoff restarts (either due to wifi, power issue or manual restart). You signed out in another tab or window. I use two reed relays connected to GPIO14 to determine door position/closed. How to set up multiple relays in Pulse Time. There are multitudes of variants and use cases. I have connected the relais to my home domotica system as an input which needs pules contact to operate a relais on 220v to control lighting, screens You can reduce the console logging like: tasmota. 8. Hello, i read through the HASPmota wiki, but i still dont understand a thing. From my understanding: I set up a timer; its trigger will Tasmota already has what you ask for. Any help would be appreciated. Example 2 (this NodeMCU v3 (nodemcu v2 clone) configured ad wemos d1 mini, only GPIO configured): Yes, the command Counter allows setting/inspecting the current value of a counter. 1 seconds until someone wanted a much bigger pulsetime (in the minutes) which was unavailable in the 16 bit pulsetime variables. 167 MQT: xxxxxxxx/stat/STATUS12 = Sign up for free to join this conversation on GitHub. , Led2/Led2i) will act as the LED that indicates the power state of the relay(s). Version: Sonoff-Tasmota 5. I use this ESP32 and Tasmota allready for measurement with DS18B20-sensors and it's working fine. If there is no There are five shutter modes which define how the relays operate. In this guide we will use GPIO13 as the pin that the PIR output is connected to. So actually changing the duty cycle by changing the period with a fixed on time. The downside may be that you cannot turn off power for good. A state text and an on/off button are automatically created on the Web GUI and syncs with the pin state. 1 seconds), while when calling URL for Power On (switch As an example my current script running on: Tasmota Version 2022. I started the developm Alternative firmware for ESP8266 and ESP32 based devices with easy configuration using webUI, OTA updates, automation using timers or rules, expandability and entirely local control over MQTT, HTTP, Serial or KNX. , water the garden from 05:00 till 07:00. They can be configured with the Timer<x> command following by a JSON string with optional parameters. Those Event commands can come More than 100 million people use GitHub to discover, fork, and contribute to over 420 million projects. View full answer . The problem is that the pulsetime value is loaded to late in the boot sequence, which can lead to the situation that a relay is turned on and pulsetime is ignored (as The test is there to save flash wear where any power change < 3 seconds induced by pulsetime is not saved to flash. I find they work very well. UPDATE: I actually changed it to just poll every minute checking the variable to see if it's past a certain count of fails, and if it fails, add 1 to the variable. * M5Stack Atom Lite IR send not receive * clarify supported E-paper displays * Update ESP32. Hi everybody, I am having issues configuring my Sonoff 4ch PRO R2 with Tasmota and Alexa. Add simple Input for entering hour/min/sec and calculate correct Puletime in Backend. It can be followed by another rule. (Need this feature because when controlling device such as boiler, I want to make sure that the device will turned off after predefined Better Interaction of Tasmota with RF chip EFM8BB1 in Sonoff RFR3 But in many real installations for example, on the ceiling, it is hard to reprogram the pairing of RF remote. excluded. PROBLEM DESCRIPTION Hitting " here's an example of using Status 12 (with a space) after a crash: 18:33:47. Example 1 (another sonoff with RELAY): mosquitto_sub -h IP -u user -P pass -t stat/sonoff1/POWER ON OFF. If you want, can you add all this to the wiki? Github issues are meant for Tasmota Software Bug Reporting. Configure the pin where the PIR is, as switch1 (for example). ino; Add support for Solax X1 inverter by Pablo Zerón; Add ZigBee support phase 1 - low level MQTT ZNP The problem is NOT with Tasmota firmware. 0a. Iˇve tried it several times, but everytime it resulted in tasm For example, if you have Relay 1 (Power1) to Relay 4 (Power4) configured on the ESP's GPIO, PCF8574 outputs will start at Power5. You switched accounts on another tab or window. Beware that if you want to process the value in Tasmota rules, that these have numerical handling as single precision floating point, meaning loss of precision above 6 digits. Hi, I am trying to compile tasmota FW including IR Remote full - SHT, BMP, DHT and DS15x20, all other sensors, displays etc. 11. That was me following the original example. You can use switchmode1 3 (to detect only if PIR sends a 1 to the Sonoff) Set a timer to be triggered when you want to control the relay with PIR I have setup two Sonoff Basics (running Tasmota) to monitor status and control garage doors. Is that a bug or intended TelePeriod"} 20:54:10 MQTT: stat/upstairs/COMMANDS3 = {"Commands3":"Power1, Power2, Light1 Light2, PowerOnState, PulseTime, BlinkTime, BlinkCount, Weblog, Webserver, WebPassword Github issues are best used for Tasmota software feature requests and bug If only one LED is configured, it serves both purposes; the link status LED and/or the LED that indicates the power state of the relay(s). Sign up for free to You signed in with another tab or window. At least for Shutter mode 1 an interlock Ideally I'd like Tasmota to report the AVERAGE frequency of the pulses directly to MQTT every 5 seconds (adjustable). This rule will set relay ON every hour, Hello! Does Pulsetime 1000 work on all relays? Is it possible to use pulsetime1 1000, for example for the first relay. For what you describe, I'd just not worry about resetting the counter all the time, but save the previous pulsetime 1000. I want to use several relays. Commands can be issued using MQTT, web requests, webUI console and serial. ) The rules should have been more like: Is there a way to show the remaing time until switch off, after trigger PulseTime? I have a sonoff Basic and use it to control my mobile electric heater. Option 2 same, don't use delay for long periods. Every command used without a parameter All of my devices are flahed with Tasmota firmware. If the pulsetime is intentionally disabled with no power parameter then the wiki needs an additional line to specify the behaviour when no parameter is given. (and 3. 1. , PulseTime 113 = 13 seconds and I would like to request to have access to the “Set” and “Remaining” value of the “Pulsetime” command within the Scripting Language. For example, turn on a relay every 5 mins for 30 seconds. cmd("Counter1", true)["Counter1"] - this does still not reduce the MQTT logging. This interface provides a means of specifying these definitions through meter descriptors. php/cmnd Skip to content Navigation Menu Add debug compile features using defines DEBUG_TASMOTA_CORE, DEBUG_TASMOTA_DRIVER and DEBUG_TASMOTA_SENSOR. For example, If you want to control your Outside Lights by SunSet and SunRise, and make them controlled by an interval timer, you can use Tasmota normal ONE-SHOT timers for turning them ON and OFF, and also add rules at boot time for the case, your device is powered up AFTER any of the ONE-SHOT timers. The device will change state after timer expired. And next Option 1 is not good. This in turn resets the counter. As mentioned I believe the issue where the relay triggers during boot-up may also have to do with the fact that I am using "Relay1i" and "Relay2i" (inverted logic relays). Navigation Menu Toggle Sign up for free to join this conversation on GitHub. but the problem is, i dont find how to do. The Sonoff's are configured to switchmode 2, pulsetime 10 and switc You can't change the Tasmota behavior to increment the timeout at each retry. For example at midday (12 hours * 60 I had exactly the same problem. Tasmota has a built in command to turn off the relay after certain period of time called "Pulsetime": PulseTime Display the amount of PulseTime remaining on the 112. mqtt command "on for 10ms" or "on for 500ms". Additionally you can define PulseTime on any relay to change the relay into a pulse relay where the pulse changes start/stop. You should use PulseTime with a short value so when performing Power ON, Tasmota will pulse ON the output for the configured time and automatically turn to off. I use an ESP Wroom32 with Tasmota 13. Reload to refresh your session. For example, when Pulse Time is 5, only the first one will take effect and the subsequent ones will not be automatically closed. I use a rule to send the PIR state to mqtt. I have homebridge setup with the mqtt-switch-tasmota plugin, and when the plugin receives a telemetry update, it is sending out an unnecessary (and annoying) command to power on. I'm sorry, but I do not understand how to get the rest running. I use PulseTime (2h) to not forget to switch it off. Then everything works as it should. Note that using tasmota. We want to turn on a pump every 5 minutes for 20 seconds using a sonoff Pow. 0*255 Skip to content. Commands over MQTT are issued by using cmnd/%topic%/<command> <parameter>. . It only works in case of a message being published at that time, within 10 seconds after 01:00, or in your additional example, at exactly second 50. here is my setup for example: The output from PIR (make sure is 3,3V) is connected directly to a GPIO (eg. Command Description; PowerOnState: Control relay state after powering up the device. Something like Event p2=300 for 5 minutes (the value you use in the RuleTimer command from the rule picking up the Event). The examples below are for a ShutterRelay1 1 configuration (using Relay1 and Relay2). Dear, I'm configuring a d1-mini with 2 components: reed switch relay The purpose is to control whether the garage door is open or closed and open the garage door through the relay. E. Notifications You must be New issue Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community C2 will count pulses and once per day will send its value by MQTT and reset itself. Also note that the counts since last saving of settings data will be lost in case of the Tasmota device getting Contribute to tasmota/docs-7. Blink is not the best solution as it is intended to perform multiple on/off cycle (although you can set the blickcount to 1). When SetOption80 1 is invoked you have to define Shutterrelay1 <value> to get started If possible to avoid any injury on unexpected movement all RELAYS should start in OFF mode when the device reboots: As Tasmota does not have the feature of "when value changed", you can do what I suggested, have the trigger compare to a var with previous value, and save current value in that var. set_power(int, bool) still results in console logging when you use that function. See DEBUG_CORE_LOG example in sonoff. Using Tasmota 6. x. My workaround is downgrade Tasmota to 5. 1 development by creating an account on GitHub. The rule that i posted was from the example and didn't test it by myself. I know that for every feature I need to compile it, but I can use that to prepare firmware to send remotely and to have device with my specified basic configuration, so if I need to I'm trying to set up a Tasmota device with complex timers. This is a pre-release copy of my water Flow Sensor for TASMOTA I have been using it for a few weeks now and it works well in my system feeding data to Grafana and NodeRed. If you set PowerOnState 5, and PulseTime 20, Tasmota can handle your power cycle timing automatically and reliably, meaning that Tasmota will turn power on again two seconds after you power off by whatever means. 250:201] events. Sounds more like a bug than an intended feature to me, as the wiki states that the power command restarts the pulsetime. There are many different meters that use the same protocol. Contribute to tasmota/docs-7. For (mostly) lights Does anyone know if the sonoff basic with firmware tasmota can be timed? for example, to to the tasmota github repository, Yes, in Tasmota console use command pulsetime. To make some or all of the specified ones "Using Timers, you can be set to turn on and off a light for iluminate a street/patio by night. Well, I carefully chose my example to avoid an issue you'd be getting into. - svalouch/tasmota-python-mqtt-influxdb-grafana-example Skip to content Navigation Menu I have electric meter with pulses working with this script on Wemos D1 (latest Tasmota with SML, Energy meters, and some sensors) >D >B ->sensor53 r >M 1 +1,4,c,1,-20,S0 1,1-0:1. Can I suggest that an area be made available that example code may be submitted to help newbies like myself. Tasmota v7. The goal is to allow a timer (MAX_TIMERS = 16) to start an "own, individual" pulsetimer, depending on the timer event. 0. Yes, it is totally possible but only with the last version of tasmota (development branch) v5. 0: Rule ON switch1#state=0 DO websend [192. By clicking “Sign up for GitHub”, Tasmota binary firmware version number used: 8. actually to turn off / on a lamp with a pulse. I want to send Current, Voltage and Power every minute from a Sonoff POW to an external system using the WEBSEND command using rules. BREAK - marks the end of a rule. how do i toggle on a circle when POWER1 is enabled/ toggled off when POWER1 is disabled. My example was totally off the cuff and when I was tired and yes, it wasn't quite correct (I left out the "DO", the "power2=1" should have been "power2 1" or "power2 on" as well as the other = symbols that should have been spaces, etc. 0 / OFF = keep relay(s) OFF after power up 1 / ON = turn relay(s) ON after power up 2 / TOGGLE = toggle relay(s) from last saved state 3 = switch relay(s) to their last saved state (default) 4 = turn relay(s) ON and disable further relay control 5 = after a PulseTime period turn relay(s) ON (acts as Tasmota web interface need improvement if more than 4 or 8 relays are present. (It can even help trigger an alarm if the door is opened without activation for example). The problem which I face up right now is about how to drive a latching relay with tasmota. I have the following rules working well on a Shelly 1PM with Tasmota 9. !!! example in case of command Backlog Power1 OFF; Delay 600; Power1 ON the usage of an additional Backlog command without any argument within the delay time of 1 minute will delete the whole queue Power1 OFF; Delay 600; Power1 ON. I didn't open the pin-gnd while typing teleperiod. Is there a way to do multiple WebQueries and update a variable based on them, like the example in the answer above? Thanks. Most PIR's are single wire and they require connecting to VCC, GND and one GPIO. Add 100 to desired interval in seconds, e. The index 0 also works with all configuration items. If more than one LED component is defined, Led1/Led1i will act as the Wi-Fi/MQTT status LED and the next defined LED (e. I did close the pin to GND (pin was in pull-up): rsl message is wrong (should be ON since inverted), teleperiod is ok. 64900 = set PulseTime for the corresponding Relay, offset by 100, in 1 second increments. Timers can be used to switch a device on or off on preset times. Thanks. I would like to read the remai To set a value to all shutter you can use the index 0. Using Delay in that way is not a reliable way of ensuring timing, as the interval can be be cut Also tasmota includes a feature for that: PulseTime. GGreg20_V3 with Generic ESP32 with Tasmota Firmware and Berry script driver example . 1 by Theo Arends GPIO5 = 33 PWM1 I can send commands, and the PWM is working, but it doesn't return the value. Now i want to have it configured on my compiled firmware. In this way, only one firmware binary version is required and a modification can be made easily on the fly. I only meant it would be good to add the reed sensor (end-stop sensors) so that tasmota can know automatically if the door is fully open / fully closed regardless of whether it triggered any action or not. github is SwitchMode1 14 !!! Please try both Good Luck. This method uses the scripting language editor to define the descriptors. It might be some noise problem in fact, but I didn't have time to dig in it. Full command Tasmota provides a powerful control interface using commands. g. See wiki for more infomation on that command. 2. A Backlog command without an argument clears a possible existing Backlog queue. So, I looked at the integrated timers of Tasmota, but not good for my use case. The way PulseTime works, you just should not set it again (unless you want a different value, of course), as it is saved persistently. The Tasmota Cookbook seems aimed at showing off what Berry can do, very admirable but not helpful to a beginner. Github issues are meant for Tasmota Software Bug Reporting and Feature So, for a smart plug, for example, Tasmota uses as small energy as possible and also it is very responsive from both, your home automation software and from the button. md Fixed omission in DevGroupSend "toggle all relays" example. After that every time I activate relay8, Sign up for a free GitHub account to open an issue and contact its maintainers and the community. Hey everyone! This is my first post here and I'd like to start by thanking everyone in this community for the wonderful Tasmota project. Therefore Power1 ON command will not be When I set PulseTime (for example: pulsetime8 10) a power1 off command is issued by tasmota device. For example ShutterPosition0 30 will move all shutters to 30%. Learn to use commands like backlog to configure your device in bulk. Typical example is for steering a model car. The general idea is: Rule1 If C1 is increased by x then VAR1 (or whatever) should increase the same amount. I thing something is wrong with my_user_config. I'm using a similar method with only rule to drive an electric heater. guopcdp addbk tjenlrl sbw lrvv dtn vlziqv qdnmf nciek bwyl